针对日益复杂多变的运行情况和系统对安全稳定经济运行的要求,提出了输电断面热稳定功率极限区间在线识别方法。首先建立输电断面热稳定功率最小极限(PTTC)和最大极限(OTTC)的优化模型,然后基于关键热稳模式筛选,采用改进Benders分解法将原问题降维、解耦,最后基于集群计算平台快速求解。所提方法为调度运行人员实时准确掌握系统安全稳定边界、动态释放输电能力提供了技术手段,某实际系统的算例分析验证了提出方法的实用性和有效性。

关键词:

基金项目:

中国南方电网有限责任公司科技项目(电网限制短路电流运行方式在线智能决策控制系统研究,0000002019030101XT00046)。

通信作者:

鲍颜红(1971—),男,通信作者,博士,研究员级高级工程师,主要研究方向:电力系统稳定分析与控制。E-mail:baoyanhong@sgepri.sgcc.com.cn

作者简介:

张金龙(1988—),男,工程师,主要研究方向:电力系统稳定分析与控制。E-mail:zhangjinlong@sgepri.sgcc.com.cn
黄磊(1987—),男,博士,高级工程师,主要研究方向:电力系统稳定分析与控制。E-mail:huanglei@csg.cn


On-line Identification Method for Thermally Stable Power Limit Interval of Transmission Section
Author:
Affiliation:

1.NARI Group Corporation (State Grid Electric Power Research Institute), Nanjing 211106, China;2.Electric Power Dispatching and Control Center of China Southern Power Grid, Guangzhou 510623, China;3.State Key Laboratory of Smart Grid Protection and Control, Nanjing 211106, China

Abstract:

To meet the requirements for the safe, stable and economic operation of power system under the increasingly complex and changing operation condition, an on-line identification method for thermally stable power limit interval of transmission section is proposed. An optimization model of thermally stable power limit is established for the pessimistic total transfer capability (PTTC) and optimistic total transfer capability (OTTC) of the transmission section. Based on screening of key thermally stable mode, the improved Benders decomposition method is used to reduce and decouple the original problem. The cluster computing platform is adopted to improve the calculation speed. The proposed method provides technical means for the dispatch operators to accurately grasp the security and stability boundaries of the system in real time and dynamically release power transmission capabilities. The analysis on an actual system example verifies the practicability and effectiveness of the proposed method.

Keywords:

Foundation:
This work is Supported by China Southern Power Grid Company Limited (No. 0000002019030101XT00046).
引用本文
[1]张金龙,鲍颜红,黄磊,等.输电断面热稳定功率极限区间在线识别方法[J].电力系统自动化,2020,44(14):79-85. DOI:10.7500/AEPS20200201003.
ZHANG Jinlong, BAO Yanhong, HUANG Lei, et al. On-line Identification Method for Thermally Stable Power Limit Interval of Transmission Section[J]. Automation of Electric Power Systems, 2020, 44(14):79-85. DOI:10.7500/AEPS20200201003.
复制
分享
历史
  • 收稿日期:2020-02-01
  • 最后修改日期:2020-03-16
  • 录用日期:
  • 在线发布日期: 2020-07-20
  • 出版日期:
相关附件