The biomechanical analysis on platform switching implants with different planting depth in front maxilla
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective In this experiment, the model of Platform Switching Implant was simulated by adopting threedimensional (3D) finite element method and the stress distribution of implants planted in different depth was analyzed when the platform switching implant system was applied with different loading in front maxilla. Method By using the Solidworks 2007 and Ansys Workbench11.0 software to simulate the 3D finite element models,the stress distribution of implants in the form of platform switching as experimental group and traditional abutment as control group which were respectively planted into the level of alveolar ridge(bone level),1 mm below bone level(minus 1) and 2 mm below bone level(minus 2) were analyzed. Results For platform switching implants, the stress of cortical bone was effectively reduced and smaller as the imlpant was planted deeper, while the traditional abutment did not change significantly with deeper planting level.Under vertical loading, the stress distribution in each model’s abutment of platform switching was basically similar, having no significant correlation with the planting depth, while the stress distribution in the traditional abutment had a significant change: gradually trending up with deeper planting level; the stress distribution of two groups of implants in each planting level and cancellous bone was basically similar, having no significant correlation with the planting depth; the stress distribution of cortical bone was shifted down with deeper planting level for platform switching group, while in the traditional abutment group, the stress distribution of cortical bone always focused on the joint between alveolar ridge top and abutment, which was more concentrated than that in platform switching group. The stress distribution under horizontal loading was similar to that under vertical loading,and the only difference was in that the maximum stress distribution of abutment and implant was mainly concentrated in their corresponding labial parts.In cortical bone, the buccal stress was obviously more concentrated than that in the vertical loading group. Conclusions Platform switching implant planted below the alveolar ridge top can improve the stress distribution, which has obvious advantages over the traditional abutment form. But the component force in horizontal direction would increase the stress on the labial part of alveolar ridge, and should be avoided.

    Reference
    Related
    Cited by
Get Citation

ZHENG Qunying, YANG Qiuyan, Du ZhiBin, CHEN Jiang. The biomechanical analysis on platform switching implants with different planting depth in front maxilla[J]. Journal of medical biomechanics,2010,25(6):417-421

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:August 02,2010
  • Revised:September 26,2010
  • Adopted:
  • Online:
  • Published: